Accurate temperature control is the key to measuring the temperature coefficient of metal resistance.Based on a temperature control device composed of PTC heating plate,micro-controller,temperature sensor,metal cavity,etc.,to achieve heating,temperature control,and temperature measurement of enameled copper wire.The improved experimental device has accurate temperature control,good linearity of experimental data.Linear correlation coefficient R 2 is over 0.999,and the measurement result is much closer to the theoretical value.
唐绪兵, 汪文明, 杜逐波, 杨祥林, 孙 云.
金属电阻温度系数测定的实验技术改进
[J]. 大学物理实验, 2023, 36(5): 53-56.
TANG Xubing, WANG Wenming, DU Zhubo, YANG Xianglin, SUN Yun .
Experimental Improvement of Measuring Resistance Temperature Coefficient with the Double Arm Bridge
. Physical Experiment of College, 2023, 36(5): 53-56.