Comparison and Analysis of the Experimental Stability of SemiconductorCooling and Forced Air Cooling in the Measurementof Thermal Conductivity by Steady-state Method
QU Zhifeng, MA Yang, WEN Kai,LI Jinrong,XIONG Bowen, YANG Zhimin*
School of Physies and Eleetrnie Information, Yan'an Universitly, Yan 'an 716000 , China
This study eritieally examines the limitations inherent in current steady state thermal eonduetivitexperimental apparatuses.To address these shortcomings, a novel setup is designed and established, integratedwith a sample holder, an adjustable regulated power supply , a digital high-precision four-channel thermometer.and a computer. A sample holder was designed and fabricated, ineorporating an aerylie plate, wing serews, aceramie heating element, and a heat sink.The thermal conductivities were tested under strong air cooling andsemiconductor heat dissipation, The results show that the up-data instrument can realize the synchronousmeasurement of temperature and time,Compared with the strong fan heat dissipation, the thermal conductivitysystem obtainedunder semiconductor heat dissipation is more stable and less noisy.The research results canprovide a relerenee for the design and aecunaey improvement of the thermal conduetivity measurement deviee othe steady state method.
屈智峰, 马 阳, 文 凯, 黎金荣, 熊博文, 杨智敏 . 稳态法导热系数测量中半导体制冷与强制风冷散热的实验稳定性对比与分析
[J]. 大学物理实验, 2025, 38(2): 6-12.
QU Zhifeng, MA Yang, WEN Kai, LI Jinrong, XIONG Bowen, YANG Zhimin. Comparison and Analysis of the Experimental Stability of SemiconductorCooling and Forced Air Cooling in the Measurementof Thermal Conductivity by Steady-state Method
. Physical Experiment of College, 2025, 38(2): 6-12.